Parameters for Primescan- Posterior Crowns
My Crown Parameter portfolio for Primescan is similar to the last few versions of Omnicam except for one. This video will review how my Parameter management has been impacted by Primescan.
The minimal thickness parameters are now set to manufacture recommendations for each material used. This will provide instant feedback with engineering "checks and balances" during the software design phase.
Comment or Post Question HERE
Minimal Thickness Radial, Occlusal, and Margin Thickness Parameters can only be modified under the individual Parameter settings in the Design Phase Screen.
Crown Parameters
Spacer 120
Proximal Contacts Strength -25
Occlusal Contacts Strength -50
Dynamic Contacts Strength -50
Occlusal Offset -200 (In Manufacture Screen)
Inlay/Onlay Parameters
Spacer 120
Margin Adhesive Gap 60
Proximal Contacts Strength -25
Occlusal Contacts Strength -50
Dynamic Contacts Strength -50
Occlusal Offset -175 (In Manufacture Screen)
Veneer Parameters
Spacer 80
Veneer Thickness 300
Occlusal Offset -175 (In Manufacture Screen)
Pontic Parameters
Proximal Contacts Strength 100
Occlusal Contacts Strength -50
Dynamic Contacts Strength -50
Gingival Spacing -300 (depends on the case)
Lingual Opening Angle 0 (depends on the case)
Occlusal Offset -200 (In Manufacture Screen)
Screw Retained Crown Parameters
Proximal Contacts Strength -25
Occlusal Contacts Strength -50
Dynamic Contacts Strength -50
Gingival Placement Pressure 0 (depends on the case)
Occlusal Offset -200 (In Manufacture Screen)
Abutment Parameters
Gingival Depth 0
Gingival Placement Pressure 0
Shoulder Width 1000
Telescope Angle 9
Abutment with Crown Parameters
Spacer 120
Proximal Contacts Strength -25
Occlusal Contacts Strength -50
Dynamic Contacts Strength -50
Occlusal Offset -200 (In Manufacture Screen)